Enclosure Fans are complete ventilation packages offering exhaust or suction air flow and are designed to provide easy installation, superior ventilation and prevent dust, moisture and foreign objects from entering. The Enclosure Fans are available with an AC or DC input fan type, offered in 3 product classes and 5 outer frame dimensions. Enclosure covers without fans are also available. Installation and maintenance is easy utilizing a square mounting hole.
Enclosure Fans types:
Fan Type |
Dimensions |
Power Supply |
Max Air |
Max Static |
||
Outer Frame Dimensions: Fan Dimensions: |
24 VDC |
77.6 ~ 91.8 CFM |
2.2 ~ 2.6 m3/min |
0.176 ~ 0.284 inH2O |
44 ~ 71 Pa |
|
Single-Phase 115 VAC |
95.3 CFM |
2.7 m3/min |
0.352 ~ 0.368 inH2O |
88 ~ 92 Pa |
||
Single-Phase 220/230 VAC |
||||||
Outer Frame Dimensions: Fan Dimensions: |
24 VDC |
49.4 ~ 63.5 CFM |
1.4 ~ 1.8 m3/min |
0.176 ~ 0.284 inH2O |
44 ~ 71 Pa |
|
Single-Phase 115 VAC |
67.7 ~ 69.9 CFM |
1.92 ~ 1.98 m3/min |
0.316 ~ 0.36 inH2O |
79 ~ 90 Pa |
||
Single-Phase 220/230 VAC |
||||||
Outer Frame Dimensions: Fan Dimensions: |
24 VDC |
30 ~ 38.8 CFM |
0.85 ~ 1.1 m3/min |
0.132 ~ 0.196 inH2O |
33 ~ 66 Pa |
|
Single-Phase 115 VAC |
28.2 ~ 35.3 CFM |
0.8 ~ 1 m3/min |
0.16 ~ 0.34 inH2O |
40 ~ 85 Pa |
||
Single-Phase 220/230 VAC |
||||||
Outer Frame Dimensions: Fan Dimensions: |
Single-Phase 110/115 VAC |
282 ~ 293 CFM |
8 ~ 8.3 m3/min |
0.8 ~ 1.16 inH2O |
200 ~290 Pa |
|
Single-Phase 220/230 VAC |
||||||
Fan Type |
Dimensions |
Power Supply |
Max Air |
Max Static |
||
Outer Frame Dimensions: Fan Dimensions: |
24 VDC |
28.2 CFM |
0.8 m3/min |
0.164 ~ 0.18 inH2O |
45 Pa |
|
Single-Phase 115 VAC |
25.1 ~ 29.3 CFM |
0.73 ~ 0.83 m3/min |
0.173 ~ 0.245 inH2O |
43 ~ 61 Pa |
||
Single-Phase 220/230 VAC |
28.2 ~ 29.3 CFM |
0.8 ~ 0.83 m3/min |
0.169 ~ 0.245 inH2O |
|
||
Outer Frame Dimensions: Fan Dimensions: |
24 VDC |
49.4 ~ 52.9 CFM |
1.4 ~ 1.5 m3/min |
0.156 ~ 0.176 inH2O |
39 ~ 44 Pa |
|
Single-Phase 115 VAC |
44.1 ~ 48.4 CFM |
1.25 ~ 1.37 m3/min |
0.165 ~ 0.225 inH2O |
41 ~ 56 Pa |
||
Single-Phase 220/230 VAC |
44.1 ~ 48.4 CFM |
1.25 ~ 1.37 m3/min |
0.161 ~ 0.225 inH2O |
40 ~ 56 Pa |
||
Outer Frame Dimensions: Fan Dimensions: |
24 VDC |
9.8 ~ 11.9 CFM |
0.28 ~ 0.34 m3/min |
0.152 ~ 0.188 inH2O |
38 ~ 47 Pa |
|
Single-Phase 115 VAC |
12.0 ~ 14.5 CFM |
0.34 ~ 0.41 m3/min |
0.181 ~ 0.253 inH2O |
45 ~ 63 Pa |
||
Single-Phase 220/230 VAC |
12.0 ~ 14.5 CFM |
0.34 ~ 0.41 m3/min |
0.169 ~ 0.253 inH2O |
42 ~ 63 Pa |
||
Outer Frame Dimensions: Fan Dimensions: |
24 VDC |
16.5 ~ 21.1 CFM |
0.47 ~ 0.6 m3/min |
0.132 ~ 0.184 inH2O |
33 ~ 46 Pa |
|
Single-Phase 115 VAC |
18.4 ~ 21.5 CFM |
0.52 ~ 0.61 m3/min |
0.149 ~ 0.225 inH2O |
37 ~ 56 Pa |
||
Single-Phase 220/230 VAC |
18.4 ~ 21.5 CFM |
0.52 ~ 0.61 m3/min |
0.136 ~ 0.225 inH2O |
34 ~ 56 Pa |
An Enclosure Fan is a combination package consisting of an axial flow fan and peripheral equipment (cover, filter media, frame and finger guard). It is suitable for cooling a control box or other enclosure.
The degree of protection and safety can be significantly improved by installing a finger guard, filter and cover, but the Air Flow - Static Pressure Characteristics differ from the fan only.
Finger Guard IP2X Type
The equipment is protected against ingress of fingers.
Slit Metal Plate IP4X Type
The equipment is protected against ingress of wires (with a diameter of 1 mm min.).
Dust and Water Protection IP43 Type
The equipment is protected against ingress of wires (with a diameter of 1 mm min.) and sprayed water (coming from directions within a range of 60° relative to the vertical plane).
Dust and Water Resistant IP55 Type
The equipment is protected against the ingress of dust and water jets (from all directions).
IP codes indicate the grade of watertight and dust-resistant performance specified under EN60529.
Thermostats (sold separately) make it possible for fans to operate only when cooling is necessary. Thermostats provide energy-saving by automatically stopping fans for example, at night, when the amount of heat generation declines following the load rate's decline in equipment, or in winter, when the ambient temperature drops and forced cooling is not necessary.
Thermostats automatically perform ON/OFF fan control in accordance with the temperature fluctuation inside the equipment. It helps improve the equipment's "environmental" performance relative to energy savings, noise reduction, etc.
Type |
Item |
Centigrade (°C) |
Additional cover panel used with enclosure fan to increase ventilation.
Item |
Dimensions |
6.34 in. (W) X 6.22 in. (H) |
Additional cover panel used with enclosure fan to increase ventilation.
Item |
Dimensions |
6.34 in. (W) X 6.22 in. (H) |
Additional cover panel used with enclosure fan to increase ventilation.
Item |
Dimensions |
7.09 in. (W) X 7.09 in. (H) |
|
11.18 in. (W) X 11.18 in. (H) |
Additional cover panel used with enclosure fan to increase ventilation.
Item |
Dimensions |
IP Rating |
6.18 in. (W) X 6.69 in. (H) |
IP43 |
|
IP55 |
||
8.23 in. (W) X 8.90 in. (H) |
IP43 |
|
IP55 |
Replacement filters forEnclosure Fans.
Sold in packages of 5 filters.
Item |
Applicable Products |
For use with 6.34 in. (W) X 6.22 in. (H) [161 mm (W) X 158 mm (H)] Finger Guard IP2X Type Enclosure Fans |
|
For use with 7.09 in. (W) X 7.09 in. (H) [180 mm (W) X 180 mm (H)] Slit Metal Plate IP4X Type Enclosure Fans |
|
For use with 6.18 in. (W) X 6.69 in. (W) [157 mm (W) X 170 mm (H)] Dust and Water Resistant IP43 Type Enclosure Fans. |
|
For use with 8.23 in. (W) X 8.9 in. (H) [209 mm (W) X 226 mm (H)] Dust and Water Resistant IP43 Type Enclosure Fans. |
|
For use with 6.18 in. (W) X 6.69 in. (W) [157 mm (W) X 170 mm (H)] Dust and Water Resistant IP55 Type Enclosure Fans. |
|
For use with 8.23 in. (W) X 8.9 in. (H) [209 mm (W) X 226 mm (H)] Dust and Water Resistant IP55 Type Enclosure Fans. |
To locate product CAD and Operator Manuals please search using the product Item Number.